Objective. Bragg peak measurements play a key role in the beam quality assurance in proton therapy. Used as base data for the treatment planning softwares, the accuracy of the data is crucial when defining the range of the protons in the patient. Approach. In this paper a protoco
...
Background
Photon counting detectors (PCDs) for x-ray computed tomography (CT) are the future of CT imaging. At present, semiconductor-based PCDs such as cadmium telluride (CdTe), cadmium zinc telluride, and silicon have been either used or investigated for clinical PCD CT. U ...
Photon counting detectors (PCDs) for x-ray computed tomography (CT) are the future of CT imaging. At present, semiconductor-based PCDs such as cadmium telluride (CdTe), cadmium zinc telluride, and silicon have been either used or investigated for clinical PCD CT. U ...
Cone-beam computed tomography (CBCT) and X-ray projection radiography are commonly used in the proton therapy workflow for the verification of patient positioning. The prospect of using the CBCT images for dose calculation purposes is attractive but currently hampered by the poor
...
Embedding signal processing in the front-end of radiation detectors represents an approach to cope with the growing complexity of nuclear imaging scanners with increasing field of view (i.e., higher number of channels). Machine learning (ML) offers a good compromise between intri
...
Objective. In radiotherapy, the internal movement of organs between treatment sessions causes errors in the final radiation dose delivery. To assess the need for adaptation, motion models can be used to simulate dominant motion patterns and assess anatomical robustness before del
...
(BZA)2PbBr4
A potential scintillator for photon-counting computed tomography detectors
Due to recent development in detector technology, photon-counting computed tomography (PCCT) has become a rapidly emerging medical imaging technology. Current PCCT systems rely on the direct conversion of X-ray photons into charge pulses, using CdTe, CZT, or Si semiconductor dete
...
Point spread function of photon-counting detectors under pile-up conditions
A proposed framework
X-ray detectors with photon-counting capabilities promise to revolutionise medical imaging. For an efficient comparison of detectors of various materials and with different setup choices, reliable detector performance measures are needed. The detector point spread function (PSF)
...
LaBr3:Ce and silicon photomultipliers
Towards the optimal scintillating photon-counting detector
We investigate fast silicon photomultiplier (SiPM)-based scintillation detectors for X-ray photon-counting applications, e.g., photon-counting computed tomography (CT). Such detectors may be an alternative to CdTe/CdZnTe (CZT) and Si detectors, which face challenges related to av
...
Background: Accuracy and precision assessment in radiomic features is important for the determination of their potential to characterize cancer lesions. In this regard, simulation of different imaging conditions using specialized phantoms is increasingly being investigated. In th
...
We investigate X-ray photon-counting scintillation detectors with silicon photomultiplier (SiPM) readout. These circumvent some drawbacks of direct-conversion detectors. We measured observed count rate (OCR) versus X-ray tube current for single-pixel detectors consisting of LYSO:
...
Breathing interplay effects in Intensity Modulated Proton Therapy (IMPT) arise from the interaction between target motion and the scanning beam. Assessing the detrimental effect of interplay and the clinical robustness of several mitigation techniques requires statistical evaluat
...
Silicon photomultiplier-based scintillation detectors for photon-counting CT
A feasibility study
Purpose: The implementation of photon-counting detectors is widely expected to be the next breakthrough in X-ray computed tomography (CT) instrumentation. A small number of prototype scanners equipped with direct-conversion detectors based on room-temperature semiconductors, such
...
The imaging performance of clinical positron emission tomography (PET) systems has evolved impressively during the last ∼15 years. A main driver of these improvements has been the introduction of time-of-flight (TOF) detectors with high spatial resolution and detection efficiency
...
Time of Flight in Perspective
Instrumental and Computational Aspects of Time Resolution in Positron Emission Tomography
The first time-of-flight positron emission tomography (TOF-PET) scanners were developed as early as in the 1980s. However, the poor light output and low detection efficiency of TOF-capable detectors available at the time limited any gain in image quality achieved with these TOF-P
...
Organ-specific, targeted field-of-view (FoV) positron emission tomography (PET)/magnetic resonance imaging (MRI) inserts are viable solutions for a number of imaging tasks where whole-body PET/MRI systems lack the necessary sensitivity and resolution. To meet the required PET det
...
A broad range of scientific and industrial disciplines require precise optical measurements at very low light levels. Single-photon detectors combining high efficiency and high time resolution are pivotal in such experiments. By using relatively thick films of NbTiN (8-11 nm) and
...
The aim of this study was to investigate the feasibility of using prompt gamma (PG) ray emission profiles to monitor changes in dose to the planning target volume (PTV) during pencil beam scanning (PBS) proton therapy as a result of day-to-day variation in patient anatomy.
...
Various methods for in vivo range estimation during proton therapy based on the measurement of prompt gamma (PG) photons have been proposed. However, optimizing the method of detection by trial-and-error is a tedious endeavor. Here, we investigate the feasibility of using the Cra
...
In proton therapy high energy protons are used to irradiate a tumor. Ideally, the delivered proton dose distribution is measured during treatment to ensure patient safety and treatment effectiveness. Here we investigate if we can use the ionoacoustic wave field to monitor the act
...