This paper presents a readout circuit for a carbon dioxide (COࠢ) sensor that measures the CO₂-dependent thermal time constant of a hot-wire transducer. The readout circuit periodically heats up the transducer and uses a phase-domain Δ Σ modulator to dig
...
The measurement of carbon-dioxide (CO2) concentration is very important in home and building automation, e.g. to control ventilation in energy-efficient buildings. This application requires compact, low-cost sensors that can measure CO2 concentration with a resolution
...
This paper reports a readout circuit capable of accurately measuring not only the resistance of a resistive transducer, but also the power dissipated in it, which is a critical parameter in thermal flow sensors or thermal-conductivity sensors. A front-end circuit, integrated in a
...
This paper reports a readout circuit for a resistive CO2 sensor, which operates by measuring the CO2-dependent thermal conductivity of air. A suspended hot-wire transducer, which acts both as a resistive heater and temperature sensor, exhibits a CO2-dependent heat loss to the sur
...