Introduction
In head-and-neck IMPT, trigger-based offline plan adaptation (Offline trigger-based) is often used. Our goal was to compare this to four alternative adaptive strategies for dosimetry, workload and treatment time, considering also foreseen further technological ad ...
Objective. In head-and-neck cancer intensity modulated proton therapy, adaptive radiotherapy is currently restricted to offline re-planning, mitigating the effect of slow changes in patient anatomies. Daily online adaptations can potentially improve dosimetry. Here, a new, fully ...
Background and purpose: In intensity modulated proton therapy (IMPT), the impact of setup errors and anatomical changes is commonly mitigated by robust optimization with population-based setup robustness (SR) settings and offline replanning. In this study we propose and evaluate ...
Purpose: To develop and evaluate a fast, automated multi-criterial treatment planning approach for adaptive high-dose-rate (HDR) intracavitary + interstitial brachytherapy (BT) for locally advanced cervical cancer. Methods and materials: Twenty-two previously delivered single fra ...