Dv
D.M. van Willigen
14 records found
1
Common clamp-on ultrasonic flow meters consist of two single-element transducers placed on the pipe wall. Flow speed is measured noninvasively, i.e., without interrupting the flow and without perforating the pipe wall, which also minimizes safety risks and avoids pressure drops i
...
Clamp-on ultrasonic flow meters (UFMs) are installed on the outside of the pipe wall. Typically, they consist of two single-element transducers mounted on angled wedges, which are acoustically coupled to the pipe wall. Before flow metering, the transducers are placed at the corre
...
This thesis describes the design, prototyping and evaluation of matrix-based clamp-on ultrasonic flow meters. Several new measurement techniques are presented as well as an Application-Specific Integrated Circuit (ASIC) designed for accurate measurement of flow velocity with matr
...
Ultrasonic flow meters (UFMs) based on transducer arrays offer several advantages. With electronic beam steering, it is possible to tune the steering angle of the beam for optimal signal-tonoise ratio (SNR) upon reception. Moreover, multiple beams can be generated to propagate th
...
Acoustic wave propagation in ultrasonic flow measurements is typically assumed to be linear and reciprocal. However, if the transmitting transducer generates a sufficiently high pressure, nonlinear wave propagation effects become significant. In flow measurements, this would tran
...
This article presents an application-specific integrated circuit (ASIC) designed for intra-vascular ultrasound imaging that interfaces 64 piezoelectric transducer elements to an imaging system using a single micro-coaxial cable. Thus, it allows a single-element transducer to be r
...
Current ultrasonic clamp-on flow meters consist of a pair of single-element transducers that are carefully positioned before use. This positioning process consists of manually finding the distance between the transducer elements, along the pipe axis, for which maximum signal-to-n
...
Transit-time ultrasonic flow meters are widely used in industry to measure fluid flow. In practice ultrasonic flow meters either show a zero-flow error or suffer from a significant random error due to a limited signal-to-noise ratio, requiring a significant amount of averaging to
...
Towards a calibration-free ultrasonic clamp-on flow meter: Pipe geometry measurements using matrix arrays
Pipe geometry measurements using matrix arrays
Current ultrasonic clamp-on flow meters are manually calibrated. This process is based on manual placement of two single-element transducers along a pipe wall. Due to the usually unknown pipe properties and inhomogeneities in the pipe geometry, the axial distance of the transduce
...
This paper presents the integration steps towards a prototype forward-looking intra-vascular ultrasound probe. An ASIC (Application Specific Integrated Circuit) is laser cut to create a 1.6mm circular shaped die that can be integrated at the tip of a small catheter. The ASIC is d
...
Clamp-on flow meters need a-priori knowledge of pipe geometry and material properties for their operation. Estimation of these properties may limit the accuracy of flow measurements. We are currently investigating the use of clamp-on flow meters based on matrix transducer arrays.
...
Current ultrasonic clamp-on flow meters are based on single-element transducers that require manual calibration by aligning these to a fixed acoustic path. Moreover, the size and operational frequency of the transducers cannot be adapted to the parameters of the pipe and the liqu
...
Transit-time ultrasonic flow meters are based on the fundamental idea that the flow is the only non-reciprocal effect between an upstream and downstream measurement. Non-identical transducers can be used in a reciprocal manner if the circuit is made reciprocal. In this paper we a
...
Typically, ultrasonic flow meters assume linear wave propagation. Nevertheless, if the transducers of an ultrasonic flow sensor excite a pressure wave with a high amplitude, nonlinear wave propagation effects become significant. The appearance of higher harmonics increases the ba
...