Surgical conditions in experimental laparoscopy
Effects of pressure, neuromuscular blockade, and pre-stretching on workspace volume
Background: Establishing a pneumoperitoneum for laparoscopy is common surgical practice, with the goal to create an optimal surgical workspace within the abdominal cavity while minimizing insufflation pressure. Individualized strategies, based on neuromuscular blockade (NMB), pre
...
Objective: To develop a realistic simulation model for laparotomy-assisted fetoscopic spina bifida aperta (SBa) surgery, to be used for training purposes and preoperative planning. Methods: The predefined general requirement was a realistic model of an exteriorized uterus, allowi
...
Introduction: Transcutaneous blood gas monitoring allows for continuous non-invasive evaluation of carbon dioxide and oxygen levels. Its use is limited as its accuracy is dependent on several factors. We aimed to identify the most influential factors to increase usability and aid
...
Age-dependent changes in arterial blood pressure in neonates during the first week of life
Reference values and development of a model
Background: Arterial pressure measurements are important to monitor vital function in neonates, and values are known to be dependent of gestational and postnatal age. Current reference ranges for mean arterial pressure in neonates have been derived from small samples and combined
...
In laparoscopic surgery the abdominal cavity is insufflated with pressurized carbon dioxide gas to create workspace. This pressure is exerted through the diaphragm onto the lungs, competing with ventilation and hampering it. In clinical practice the difficulty of optimizing this
...
Background: During minimal access surgery, surgical smoke is produced which can potentially be inhaled by the surgical team, leading to several health risks. This smoke can escape from the abdominal cavity into the operating room due to trocar leakage. The trocars and insufflator
...
Background: In neonates with post-asphyxial neonatal encephalopathy, further neuronal damage is prevented with therapeutic hypothermia (TH). In addition, fluctuations in carbon dioxide levels have been associated with poor neurodevelopmental outcome, demanding close monitoring. T
...
Background: Abdominal compliance describes the ease of expansion of the abdominal cavity. Several studies highlighted the importance of monitoring abdominal compliance (Cab) during the creation of laparoscopic workspace to individualize the insufflation pressure. The l
...
Introduction: Traditional transcutaneous oxygen (tcPO2) measurements are affected by measurement drift, limiting accuracy and usability. The new potentially drift-free oxygen fluorescence quenching technique has been combined in a single sensor with conventional transcutaneous ca
...
Background
During laparoscopy, the abdominal cavity is insufflated with carbon dioxide (CO2) that could become contaminated with viruses and surgical smoke. Medical staff is potentially exposed when this gas leaks into the operating room through the instruments and past troca ...
During laparoscopy, the abdominal cavity is insufflated with carbon dioxide (CO2) that could become contaminated with viruses and surgical smoke. Medical staff is potentially exposed when this gas leaks into the operating room through the instruments and past troca ...
Introduction: Evaluation of pharmacotherapy during intensive care treatment is commonly based on subjective, intermittent interpretations of physiological parameters. Real-time visualization and analysis may improve drug effect evaluation. We aimed to evaluate the effects of the
...
This study investigated the accuracy, drift, and clinical usefulness of a new optical transcutaneous oxygen tension (tcPO2) measuring technique, combined with a conventional electrochemical transcutaneous carbon dioxide (tcPCO2) measurement and reflectance p
...
Dynamic Light Scattering
A New Noninvasive Technology for Neonatal Heart Rate Monitoring
Heart rate (HR) detection in premature infants using electrocardiography (ECG) is challenging due to a low signal amplitude and the fragility of the premature skin. Recently, the dynamic light scattering (DLS) technique has been miniaturized, allowing noninvasive HR measurements
...