IR
Irwin Reiss
18 records found
1
Electrical Impedance Tomography as a monitoring tool during weaning from mechanical ventilation
An observational study during the spontaneous breathing trial
Background: Prolonged weaning from mechanical ventilation is associated with poor clinical outcome. Therefore, choosing the right moment for weaning and extubation is essential. Electrical Impedance Tomography (EIT) is a promising innovative lung monitoring technique, but its rol
...
Development of a Web-Based Oxygenation Dashboard for Preterm Neonates
A Quality Improvement Initiative
Background: Preterm neonates are extensively monitored to require strict oxygen target attainment for optimal outcomes. In daily practice, detailed oxygenation data are hardly used and crucial patterns may be missed due to the snapshot presentations and subjective observations. T
...
Age-dependent changes in arterial blood pressure in neonates during the first week of life
Reference values and development of a model
Background: Arterial pressure measurements are important to monitor vital function in neonates, and values are known to be dependent of gestational and postnatal age. Current reference ranges for mean arterial pressure in neonates have been derived from small samples and combined
...
Introduction: Transcutaneous blood gas monitoring allows for continuous non-invasive evaluation of carbon dioxide and oxygen levels. Its use is limited as its accuracy is dependent on several factors. We aimed to identify the most influential factors to increase usability and aid
...
Inside the Neonatal Intensive Care Unit (NICU), exposure to loud sounds such as acoustic medical alarms can have adverse effects on neonates, parents, and medical staff. With the aim of having an accurate overview of which and how often acoustic medical alarms occur, this paper p
...
Background: In neonates with post-asphyxial neonatal encephalopathy, further neuronal damage is prevented with therapeutic hypothermia (TH). In addition, fluctuations in carbon dioxide levels have been associated with poor neurodevelopmental outcome, demanding close monitoring. T
...
Introducing heart rate variability monitoring combined with biomarker screening into a level IV NICU
A prospective implementation study
The aim of this study was to investigate the association between the
implementation of a local heart rate variability (HRV) monitoring
guideline combined with determination of inflammatory biomarkers and
mortality, measures of sepsis severity, frequency of sepsis testing, and
...
Predictive Intelligent Control of Oxygenation in Preterm Infants
A Two-Center Feasibility Study
Introduction: Supplemental oxygen therapy is a mainstay of modern neonatal intensive care for preterm infants. However, both insufficient and excess oxygen delivery are associated with adverse outcomes. Automated or closed loop FiO2 control has been developed to keep SpO2 within
...
Introduction: Traditional transcutaneous oxygen (tcPO2) measurements are affected by measurement drift, limiting accuracy and usability. The new potentially drift-free oxygen fluorescence quenching technique has been combined in a single sensor with conventional transcutaneous ca
...
This study investigated the accuracy, drift, and clinical usefulness of a new optical transcutaneous oxygen tension (tcPO2) measuring technique, combined with a conventional electrochemical transcutaneous carbon dioxide (tcPCO2) measurement and reflectance p
...
Background: Non-invasive monitoring of cerebral tissue oxygen saturation (rcSO2) during transition is of growing interest. Different near-infrared spectroscopy (NIRS) techniques have been developed to measure rcSO2. We compared rcSO2 values during
...
Dynamic Light Scattering
A New Noninvasive Technology for Neonatal Heart Rate Monitoring
Heart rate (HR) detection in premature infants using electrocardiography (ECG) is challenging due to a low signal amplitude and the fragility of the premature skin. Recently, the dynamic light scattering (DLS) technique has been miniaturized, allowing noninvasive HR measurements
...
Monitoring of respiratory rate (RR) is very important for patient assessment. In fact, it is considered one of the relevant vital parameters in critical care medicine. Nowadays, standard monitoring relies on obtrusive and invasive techniques, which require adhesive electrodes or
...
BACKGROUND AND PURPOSE: Infants born preterm are commonly diagnosed with structural brain lesions known to affect long-term neurodevelopment negatively. Yet, the effects of preterm birth on brain development in the absence of intracranial lesions remain to be studied in detail. I
...
The aim was to assess the reproducibility of the Pleth Variability Index (PVI), developed for non-invasive monitoring of peripheral perfusion, in preterm neonates below 32 weeks of gestational age. Three PVI measurements were consecutively performed in stable, comfortable preterm
...
The developing human fetus is able to cope with the physiological reduction in oxygen supply occurring in utero. However, it is not known if microvascularization of the fetus is augmented when pregnancy occurs at high altitude. Fifty-three healthy term newborns in Puno, Peru (3,8
...
Oxygen therapy in preterm infants is mainly concerned with finding a balance between the need for additional oxygen and preventing damage due to oxygen free radicals. [1] But However, oxygen therapy is about more than providing additional oxygen. It also includes the transportati
...
Reference ranges for regional cerebral tissue oxygen saturation (crSO 2) reported by Pichler et al are an important step towards implementation of crSO2 monitoring during resuscitations. 1 At the Erasmus Medical Centre, Rotterdam, we found a surprising crSO2 observation in the fi
...