JS
J.L. Silva Canaveira Tourais
14 records found
1
Purpose
To optimize Relaxation along a Fictitious Field (RAFF) pulses for rotating frame relaxometry with improved robustness in the presence of B0 and B1+ field inhomogeneities.
Methods
The resilience of RAFF pulses against B0 and B1+ inhomogeneities was studied ...
To optimize Relaxation along a Fictitious Field (RAFF) pulses for rotating frame relaxometry with improved robustness in the presence of B0 and B1+ field inhomogeneities.
Methods
The resilience of RAFF pulses against B0 and B1+ inhomogeneities was studied ...
Purpose: Evaluate the feasibility of quantification of Relaxation Along a Fictitious Field in the 2nd rotating frame (RAFF2) relaxation times in the human myocardium at 3 T.
Methods: TRAFF2 mapping was performed using a breath-held ECG-gated acquisition of five images: o ...
Methods: TRAFF2 mapping was performed using a breath-held ECG-gated acquisition of five images: o ...
Purpose: To develop and evaluate a robust cardiac B+1 mapping sequence at 3 T, using Bloch–Siegert shift (BSS)-based preparations.
Methods: A longitudinal magnetization preparation module was designed to encode |B+1 |. After magnetization tip-down, off-resonant Fermi pul ...
Methods: A longitudinal magnetization preparation module was designed to encode |B+1 |. After magnetization tip-down, off-resonant Fermi pul ...
Objective: Quantitative Magnetic Resonance Imaging (MRI) holds great promise for the early detection of cartilage deterioration. Here, a Magnetic Resonance Fingerprinting (MRF) framework is proposed for comprehensive and rapid quantification of T
1, T
...
Purpose: The aim of this study is to develop and optimize an adiabatic (Formula presented.) ((Formula presented.)) mapping method for robust quantification of spin-lock (SL) relaxation in the myocardium at 3T. Methods: Adiabatic SL (aSL) preparations were optimized for resilience
...
Purpose: To develop a free-breathing (FB) 2D radial balanced steady-state free precession cine cardiac MRI method with 100% respiratory gating efficiency using respiratory auto-calibrated motion correction (RAMCO) based on a motion-sensing camera. Methods: The signal from a respi
...
With sound pressure levels reaching up to 130 dB, acoustic noise in Magnetic Resonance Imaging (MRI) is one of the main sources of patient discomfort in otherwise one of the safest medical imaging modalities. In this work, a noise prediction-based approach, termed predictive nois
...
Magnetic Resonance Imaging (MRI) is the clinical gold standard for the assessment of myocardial viability but requires injection of exogenous gadolinium-based contrast agents. Recently, T1ρ-mapping has been proposed as a fully non-invasive alternative for imaging myocardial fibro
...
Introduction: To develop and test the feasibility of free-breathing (FB), high-resolution quantitative first-pass perfusion cardiac MR (FPP-CMR) using dual-echo Dixon (FOSTERS; Fat-water separation for mOtion-corrected Spatio-TEmporally accelerated myocardial peRfuSion). Material
...
Ischemic heart disease (IHD) is one of the leading causes of death worldwide. Myocardial infarction (MI) represents a third of all IHD cases, and cardiac magnetic resonance imaging (MRI) is often used to assess its damage to myocardial viability. Late gadolinium enhancement (LGE)
...
Background: Respiratory gating is generally recommended in 4D flow MRI of the heart to avoid blurring and motion artifacts. Recently, a novel automated contact-less camera-based respiratory motion sensor has been introduced. Purpose: To compare camera-based respiratory gating (CA
...
Magnetic Resonance Imaging compatible Elastic Loading Mechanism (MELM)
A minimal footprint device for MR imaging under load
Quantitative Magnetic Resonance Imaging (MRI) can enable early diagnosis of knee cartilage damage if imaging is performed during the application of load. Mechanical loading via ropes, pulleys and suspended weights can be obstructive and require adaptations to the patient table. I
...
Purpose: To develop a new 3D radial trajectory based on the natural spiral phyllotaxis (SP), with variable anisotropic FOV. Theory & Methods: A 3D radial trajectory based on the SP with favorable interleaving properties for cardiac imaging has been proposed by Piccini et al (
...
Image processing methods for PET/MR multi-modality imaging
Initial study regarding binding of MR images
The combination of Positron Emission Tomography (PET) and Magnetic Resonance Imaging (MRI) has gained attention over the past five years due to the complementary advantages of these modalities [1]. Whole-Body (WB) PET/MR systems for clinical applications still have room for impro
...