GZ

9 records found

As the existing bridge stock is aging, assessment of existing bridges becomes increasingly important. In the Netherlands, the shear capacity of reinforced concrete slab bridges is found to be insufficient. In particular, the shear and punching shear capacity of reinforced concret ...
Proof load testing for assessment can involve a large risk due to the high loads. Stop criteria can reduce this risk. Stop criteria are necessary for shear, which is a brittle failure mode. This paper describes the development of shear stop criteria for slab strips. The shear sto ...
Advanced monitoring methods are required to identify stop criteria in proof-load tests. In this study, the combined methodology of two-dimensional digital image correlation and acoustic emission is investigated for its applicability for future implementation in field tests. The t ...
Nowadays, with the aging of the bridges and the advancements in technology, load testing has emerged as an effective method to assess existing concrete bridges with missing information, or where analytical methods do not provide an accurate assessment. Two types of load tests are ...
In the Netherlands, many existing reinforced concrete slab bridges were built more than 50 years ago. Upon assessment with the new codes, a large number of this type of bridge rate insufficiently. Since many of these existing bridges present complex material properties and bounda ...
For the assessment of existing slab-between-girder bridges, the shear capacity and failure mode are under discussion. Previous research showed that the static and fatigue punching capacity of the slabs is sufficient as a result of compressive membrane action. The girders then bec ...
Proof load testing can be an interesting method to assess existing bridges for which analytical methods are unable to provide an accurate assessment. In a proof load test, a load representative of the factored live load is applied to the bridge. If the bridge can carry this load ...
In the Netherlands, many prestressed concrete bridge girders are found to have insufficient shear–tension capacity. We tested four girders taken from a demolished bridge and instrumented these with traditional displacement sensors and acoustic emission (AE) sensors, and used came ...
Existing bridges with large uncertainties can be assessed with proof load tests. In such tests, a load representative of the factored live load is applied to the structure. If the bridge can carry the load without any signs of distress or nonlinearity, the test is considered succ ...