N. Bhattacharya
77 records found
1
In measuring cerebral blood flow (CBF) noninvasively using optical techniques, diffusing-wave spectroscopy is often combined with near-infrared spectroscopy to obtain a reliable blood flow index. Measuring the blood flow index at a determined depth remains the ultimate goal. In t
...
The disease atherosclerosis causes stenosis inside the patient's arteries, which often eventually turns lethal. Our goal is to detect a stenosis in a non-invasive manner, preferably in an early stage. To that end, we study whether and how laser speckle contrast imaging (LSCI) can
...
The dependence of speckle contrast on velocity
A numerical study
We study how the speckle contrast depends on scatterer velocity, with the goal of further developing laser speckle imaging as a quantitative measurement technique. To that end, we perform interferometric computer simulations on a dilute plug flow. The results of our numerical exp
...
The measurement of distance plays an important role in many aspects of modern societies. In this paper, an absolute distance measurement method for arbitrary distance is proposed and demonstrated using mode-resolved spectral interferometry with a gain-switched dual comb. An accur
...
Distance measurement using frequency sweeping interferometry is an absolute distance measurement technique that allows for high accuracy over long distances. Notwithstanding, the measurement accuracy is affected by laser sweeping nonlinearity and limited sweeping range. In this w
...
Laser speckle imaging of flowing blood
A numerical study
Laser speckle imaging (LSI) can be used to study dynamic processes in turbid media, such as blood flow. However, it is presently still challenging to obtain meaningful quantitative information from speckle, mainly because speckle is the interferometric summation of multiply scatt
...
The measurement of distance plays an integral part in many aspects of modern societies. In this paper an integrated mode-locked laser on a chip is used for distance measurement based on mode-resolved interferometry. The emission from the on-chip source with a repetition rate of 2
...
We describe a method to control the directional scattering of a high-index dielectric nanosphere, which utilizes the unique focusing properties of an azimuthally polarized phase vortex and a radially polarized beam to independently excite inside the nanosphere a spinning magnetic
...
In this paper a generic monolithic photonic integration technology platform and tunable laser devices for gas sensing applications at 2 μm will be presented. The basic set of long wavelength optical functions which is fundamental for a generic photonic integration approach is rea
...
In this work we present a design of an external optical cavity based on Fabry-Perot etalons applied to a 100 MHz Er-doped fiber optical frequency comb working at 1560 nm to increase its repetition frequency. A Fabry-Perot cavity is constructed based on a transportable cage system
...
The scattering of coherent light from a system with underlying flow can be used to yield essential information about dynamics of the process. In the case of pulsatile flow, there is a rapid change in the properties of the speckle images. This can be studied using the standard las
...
Exhaled breath analysis is a potential non-invasive tool for diagnosing and monitoring airway diseases. Gas chromatography-mass spectrometry and electrochemical sensor arrays are the main techniques to detect volatile organic compounds (VOC) in exhaled breath. We developed a broa
...
We present a widely tunable extended cavity ring laser operating at 2 μm that is monolithically integrated on an indium phosphide substrate. The photonic integrated circuit is designed and fabricated within a multiproject wafer run using a generic integration technology platform.
...
Monolithic integration of four widely tunable extended cavity lasers suitable for gas detection is presented. Each laser features a precise, grid-less tuning mechanism with a low-linewidth, single-mode output over a wide wavelength range of 74nm.@en
The existence of non-radiating sources is of fundamental importance for inverse scattering problems and the design of invisible objects. However, the excitation of such radiationless sources is quite challenging. We present a method based on which the anapole mode of a high-index
...
A new Method for Processing Time Averaged Vibration Patterns
Linear Regression
Speckle-based interferometry systems are useful tools for measuring vibration patterns at harmonically vibrating objects. The standard method for processing the speckle patterns acquired is to eliminate additive background noise and speckle phase, yielding Bessel-type fringe patt
...
Progress on the development of a long wavelength (∼2 μm) generic monolithic photonic integration technology on indium phosphide substrate and a novel concept of a tunable laser realized as a photonic integrated circuit using such technology are presented. Insights into the develo
...