Accurate needle placement in deep-seated liver tumours can be difficult. In this work, we disclose two new manually controlled steerable needles for 17G radio-frequency ablation probe placement. The needles contain stylets with embedded compliant joints for active tip articulatio
...
Purpose: To present a novel methodical approach to compare visibility of percutaneous needles in ultrasound images. Methods: A motor-driven rotation platform was used to gradually change the needle angle while capturing image data. Data analysis was automated using block-matching
...
Ultrasound-Guided Percutaneous Liver Biopsy
A Review on Obtaining Adequate Specimens
This literature review was conducted to evaluate liver biopsy adequacy, including total core length (TCL), number of portal tracts (PT), fragmentation, and complication rates, as a function of needle type and gauge. A systematic electronic search was performed in the Web of Scien
...
We propose a consistent ultrasound volume stitching framework, with the intention to produce a volume with higher image quality and extended field-of-view in this work. Directly using pair-wise registrations for stitching may lead to geometric errors. Therefore, we propose an app
...
Purpose: The purpose is to design and validate an anthropomorphic polyvinyl alcohol (PVA) liver phantom with respiratory motion to simulate needle-based interventions. Such a system can, for example, be used as a validation tool for novel needles. Methods: Image segmentations of
...
In this work we present a fast approach to perform registration of computed tomography to ultrasound volumes for image guided intervention applications. The method is based on a combination of block-matching and outlier rejection. The block-matching uses a correlation based multi
...
Purpose: Accurate and precise needle placement is of utmost importance in interventional radiology. However, targeting can be challenging due to, eg, tissue motion and deformation. Steerable needles are a possible solution to overcome these challenges. The present work studied th
...
Multi-modal registration, especially CT/MR to ultrasound (US), is still a challenge, as conventional similarity metrics such as mutual information do not match the imaging characteristics of ultrasound. The main motivation for this work is to investigate whether a deep learning n
...
Needle deflection in thermal ablation procedures of liver tumors
A CT image analysis
Introduction: Accurate needle placement is crucial in image-guided needle interventions. A targeting error may be introduced due to undesired needle deflection upon insertion through tissue, caused by e.g. patient breathing, tissue heterogeneity, or asymmetric needle tip geometri
...
Multimodal image fusion for image guidance in minimally invasive liver interventions generally requires the registration of pre-operatively acquired images with interventional images of the patient. Whereas rigid registration approaches are fast and can be used in an intervention
...
In minimal invasive image guided catheterization procedures, physicians require information of the catheter position with respect to the patient's vasculature. However, in fluoroscopic images, visualization of the vasculature requires toxic contrast agent. Static vasculature road
...
Augmenting X-ray imaging with 3D roadmap to improve guidance is a common strategy. Such approaches benefit from automated analysis of the X-ray images, such as the automatic detection and tracking of instruments. In this paper, we propose a real-time method to segment the cathete
...
CT-guided percutaneous ablation for liver cancer treatment is a relevant technique for patients not eligible for surgery and with tumors that are inconspicuous on US imaging. The lack of real-time imaging and the use of a limited amount of CT contrast agent make targeting the tum
...
Purpose: In image-guided radio frequency ablation for liver cancer treatment, pre- and post-interventional CT images are typically used to verify the treatment success of the therapy. In current clinical practice, the tumor zone in the diagnostic, preinterventional images is ment
...
In this work we describe a 4D registration method for on the fly stabilization of ultrasound volumes for improving image guidance for transjugular intrahepatic portosystemic shunt (TIPS) interventions. The purpose of the method is to enable a continuous visualization of the relev
...
Erratum
An automatic registration method for pre- and post-interventional CT images for assessing treatment success in liver RFA treatment (Medical Physics (2015) 42 (5559-5567))
Liver vessel segmentation in CTA images is a challenging task, especially in the case of noisy images. This paper investigates whether pre-filtering improves liver vessel segmentation in 3D CTA images. We introduce a quantitative evaluation of several well-known filters based on
...