Silicon photonic opto-mechanical ultrasound sensor for photoacoustic imaging
More Info
expand_more
expand_more
Abstract
Future applications of photo-acoustic imaging require a matrix of small (wavelength/2) and sensitive ultrasound sensors with read-out through a flexible cable. Integrated optical sensors have good prospects: small and sensitive sensors, wafer-scale fabrication, and matrix read-out via single optical fiber using on-chip optical multiplexing. We propose a new type of opto-mechanical ultrasound sensor (OMUS) in silicon photonic chip technology. By using an acoustically resonant membrane in combination with an innovative split rib-type photonic waveguide, we achieve extremely high sensitivity. We present our experimental results in the frequency range up to 30 MHz.