Eddy-current loss prediction in the rotor magnets of a permanent magnet synchronous generator with modular winding feeding a rectifier load
More Info
expand_more
expand_more
Abstract
In a permanent magnet synchronous generator (PMSG) with modular winding, significant eddy current may be induced in the rotor magnets due to asynchronous rotating stator magneto-motive forces (MMFs), and a rectifier load may signify the situation further. The eddy-current loss prediction in the rotor magnets of a PMSG with modular winding feeding a rectifier load is described. An analytical method considering the stator current harmonics and stator MMF spatial harmonics and a time-stepping, coupled-circuit, 2-D finite-element method (FEM) are adopted. The predicted losses obtained from these two methods are compared and investigated.
No files available
Metadata only record. There are no files for this journal article.