Eddy-current loss prediction in the rotor magnets of a permanent magnet synchronous generator with modular winding feeding a rectifier load

More Info
expand_more

Abstract

In a permanent magnet synchronous generator (PMSG) with modular winding, significant eddy current may be induced in the rotor magnets due to asynchronous rotating stator magneto-motive forces (MMFs), and a rectifier load may signify the situation further. The eddy-current loss prediction in the rotor magnets of a PMSG with modular winding feeding a rectifier load is described. An analytical method considering the stator current harmonics and stator MMF spatial harmonics and a time-stepping, coupled-circuit, 2-D finite-element method (FEM) are adopted. The predicted losses obtained from these two methods are compared and investigated.