A Measurement of the Wheel-Rail Contact Temperature Field
More Info
expand_more
Abstract
As a critical factor in the degradation of rails and wheels, wheel-rail contact heat has been investigated with various analytical and numerical methods. However, the predicted temperature distributions and thermal loads have not been directly validated through measurements due to the challenges associated with accurate measurements. This study employs an infrared camera to measure the temperature variation at the wheel-rail contact under various slip ratio conditions in an in-house wheel-rail dynamic contact test rig. Wheel braking is replicated, and a wheel flat is generated. The temperature field of the contact interface is measured and analyzed, revealing the heating and cooling processes before and after the formation of the wheel flat. The results demonstrate that the contact temperature between the wheel and rail progressively increases with increasing slip ratio until a flat is formed. Notably, at a slip ratio of 8.3%, the observed contact temperature reaches 337.2 ℃ and then rises to 432.8 ℃ at a higher slip ratio of 15.9%. When the wheel flat is generated at a slip ratio of 20.4%, the observed contact temperature between the wheel and rail reaches 652.4 ℃. After the formation of the flat, the contact temperature initially decreases due to more wheel material of lower temperature entering into the contact and rises again with the increase of slip ratio. These measurement findings are valuable for calibrating and validating simulation models and investigating thermal damage related to wheel-rail interactions.
Files
File under embargo until 01-05-2025