Comparison of levelized cost of energy of superconducting direct drive generators for a 10-MW offshore wind turbine
More Info
expand_more
expand_more
Abstract
A method for comparing the levelized cost of energy (LCoE) of different superconducting drive trains is introduced. The properties of a 10-MW MgB2 superconducting direct-drive generator and the cost break down of the nacelle components are presented and scaled up to a turbine with a rotor diameter of up to 280 m. The partial load efficiency of the generator is evaluated for a constant cooling power of 0, 50, and 100 kW, and the annual energy production is used to determine the impact on the LCoE.
Files
08304589.pdf
(pdf | 0.551 Mb)
Unknown license
Download not available
Comparison_of_Levelized_Cost_o... (pdf)
(pdf | 0.581 Mb)
- Embargo expired in 28-08-2018
Unknown license